Where a 13.8V SMPSU is used directly to power an HF Tx/Rx the normal mains & DC
filtering is often inadequate to remove all the switch mode spogies that a
sensitive Rx & nearby aerial can pick up.
0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 MHz
Typical QRM as measured on a commercial "RADIO HAM SMPSU" using a 50kHz wide
spectrum analyser. The 'S' meter readings depends on your Rig's QRM imunity to
power rail QRM as well as the SMPSU radiation & pickup to your aerial.
SMPSU often pulse on & off on no load, this is good indication that the
following Rx QRM elimination method will work 100%. But before you under take a
SMPSU modification, test the principle works OK with a variable bench PSU
first. If the test is OK & not too high a voltage is needed (watch those dial
lamps if over 15V!), then look for room inside the SMPSU or add a bolt on box
to the SMPSU unit if you like (case as heatsink).
The strategy is to stop the SMPSU from running while on Rx, by using a small
linear PSU for Rx instead. Stopping the SMPSU running is normally possible on
all SMPSU if the output goes slightly higher than the nominal 13.8V by only a
few 100mV. Note that too much overvoltage may trigger a crowbar overvoltage
circuit if that sort of protection is built in (I recommend U add one if not).
On a good insulated Heatsink
Linear Rx PSU Noisy PSU
diodes 1N4001 or better.
The rating of the current limiting linear PSU needs to be just enough to run
the Rx at normal volume etc. Normally 1A will do, but 2 x 1A regs could be used
in parallel (with an 0R1 Rs in each output) if 1A is not enough, or use some
other regulator.
Other than eliminating the SMPSU QRM there is 1A more current available on Tx.
The regulator(s) must be the current limiting type & well heatsinked, as it
will be working very hard all the time!
See my bul "Reducing Electronic RF QRM" for more tips.