This is quite a complex circuit design with 2 relays etc.
DIAGRAM
X=No of Contacts o = PCB Connection * = External Connection
OPERATION
After rotating the HEADING pot to the desired direction and pressing the START
button the LED is lit. Then the CW RELAY (Clockwise) either operates or stays
released, this determines the AC phase direction selected for the motor. In
either case the RUN relay is powered until the balance point of the 2 pot
resistance bridge is reached when Q1, Q2, and the CW relay change state. The
RUN relay is then fast released with reverse power and the mains supply is
disconnected and the LED extinguishes.
Preset pots VR1 & VR2 set the scale length for both the HEADING & ROTATOR pots,
and should be set so that the rotator always stops before the mechanical end
stop is reached at either end of the HEADING pot.
MODS
As with other rotators the motor is well over run, so if you want more than 2
mins run time add a high wattage low value R (e.g. 8R 10W) in series with the
CW2 switch common, this will increase motor run time before it overheats or
burns out!