By G8MNY                                       (Updated Jan 23)
(8 Bit ASCII graphics use code page 437 or 850, Terminal Font)

This is a reliable rotator with manual L & R switches and servo motor driven

different makers. It is almost identical to the KR600, that just has an extra
wire & added motor stop switches.











DIAGRAM             __
                  /Dial\
































                                          Motor Common





















     o = Internal PCB wiring points          * = External Terminals


COMPONENT
No   R    |  No    R      C      D        Q      VR    L       B
13  10k   |   1   220    10n  1N4002  2SC1815   20k  220uH  14V Bulb
14   1k   |   2   220   100u  1N4002  2SA1015   20k  220uH
15   1k   |   3   10k   100u  1N4002  LM 741    10k
16  390   |   4   10k    10n  1N4002  NMJ4558   500
17  820   |   5   150    10n  1S1588  2SC1815   500
18  47k   |   6   150    10n  1S1588  2SC1815
19  33k   |   7  560k    10n   WZ130
20  330   |   8  560k    10n   WZ130
21  10k   |   9   10k   100u
22   1k   |  10   10k    10n
23  820   |  11  150k    10n
24  5k6   |  12  150k   100u AC
25   2

Common faults..
I have seen on more than one occasion, a split in the plastic pinion on the DC
dial motor. This causes the dial hunting as the display servo can't find the
matching dial pot balance. The cure is to remove the motor carefully slide the
pinion off. Roughen up the D shaped shaft, and using a resin glue, glue back on
the pinion, maintaining pressure across the crack until the glue has hardened,
then reassemble & test.

John G0JOP has had to replace the op-amp on his, I bet this was due to static
or mis-wire on pin 15 straight into the IC! Adding a few k ohm in series with
the inductors L1 & L2 & 4 diodes on inputs to +/- rails may give protection!

A problem Bryan G6ODE found was a loose pinion gear on the motor shaft in the
rotator, that glued up OK as a fix.

Another problem Brian G8VPR mentions is the Rotator Pot going open circuit, so
this the circuit should help do tests.

MODIFICATIONS
I use mine for /P work and have done some mods...

1/ Add a 22R in series with the lamp, to improve lamp lifetime.

2/ Add an 8R 10W in series with motor common on the transformer (*6*) reduces
   the super saturation of the motor on 240V 50Hz on low loss leads. As the
   motor can work down to 18V with hardly any loss of torque, and for much


3/ Added a 0.47uF 300V AC across the 240V mains, to Power Factor correct the
   permanent transformer load.

4/ Keep the pointer screw just loose enough for fine manual direction
   adjustment.

5/ Wire colour coded labels and terminal screws.
  
6/ Heavy duty 6 way plug socket on long lead to ease dismantilling.


Why don't U send an interesting bul?

73 de John G8MNY @ GB7CIP