Years ago I bought a large not working 19" LAB DMM (Datron 1061a). It is an
extremely precise 7.5 digits DMM for its time of 1983. Luckily it came with all
the handbooks and I am pleased to say is quite serviceable now after finding a
silly PCB plug fault.
Here is part of the exacting specification...
+/- 1.999999 on most ranges with the filtering & averaging options in.
DC VOLTS Input Z ---- Accuracy since last Cal------
Range: 24hr, 90 day, 1 year
DC CURRENT ---- Accuracy since last Cal------
Range: 24hr, 90 day, 1 year
RESISTANCE Test ---- Accuracy since last Cal------
Range: Current 24hr, 90 day, 1 year
it also measures in circuit 1 of 3 Rs.
AC RMS VOLTS Input Z ---- Accuracy since last Cal------
Range 24hr, 90 day, 1 year
Frequency Response flat 10Hz - 1MHz @ -2%
True RMS measurements to 7:1 crest to mean factor.
AC RMS CURRENT ---- Accuracy since last Cal------
Range: 24hr 90 day, 1 year
0.1-1A 0.1%, 0.2%, 0.3%
Shunts: as DC
True RMS measurements to 3:1 crest to mean factor.
Other features:
AC+DC True RMS option for Volts & Current as AC ranges.
Local or seperate screen guard system.
IEEE interface for automatic readings/logging.
Go/fail % testing.
Reading accuracy calculation.
Direct entry number keyboard.
Pre use calibrated self check.
Security key locked calibration, easy press button cal features.
See my tech bul on "Measuring 1 of 3 Rs"
Why Don't U send an interesting bul?
73 De John, G8MNY @ GB7CIP